Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Blood ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691679

RESUMO

Serial cardiovascular magnetic resonance evaluation of children and young adults with sickle cell disease (SCD) who underwent hematopoietic cell transplantation (HCT) showed that the mean ECV, representing diffuse myocardial fibrosis, decreased by 3.4% from the baseline to 12-months post HCT. (NCT04362293).

3.
Pediatr Radiol ; 54(5): 684-692, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38332355

RESUMO

As the field of three-dimensional (3D) visualization rapidly advances, how healthcare professionals perceive and interact with real and virtual objects becomes increasingly complex. Lack of clear vocabulary to navigate the changing landscape of 3D visualization hinders clinical and scientific advancement, particularly within the field of radiology. In this article, we provide foundational definitions and illustrative examples for 3D visualization in clinical care, with a focus on the pediatric patient population. We also describe how understanding 3D visualization tools enables better alignment of hardware and software products with intended use-cases, thereby maximizing impact for patients, families, and healthcare professionals.


Assuntos
Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Criança , Software , Pediatria/métodos , Radiologia/métodos
6.
Invest Radiol ; 57(12): 802-809, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36350068

RESUMO

OBJECTIVE: The 2-point DIXON method is widely used to assess fat fractions (FFs) in magnetic resonance images (MRIs) of the tongue, pharyngeal wall, and surrounding tissues in patients with obstructive sleep apnea (OSA). However, the method is semiquantitative and is susceptible to B0 field inhomogeneities and R2* confounding factors. Using the method, although several studies have shown that patients with OSA have increased fat deposition around the pharyngeal cavity, conflicting findings was also reported in 1 study. This discrepancy necessitates that we examine the FF estimation method used in the earlier studies and seek a more accurate method to measure FFs. MATERIALS AND METHODS: We examined the advantages of using the GOOSE (globally optimal surface estimation) method to replace the 2-point DIXON method for quantifying fat in the tongue and surrounding tissues on MRIs. We first used phantoms with known FFs (true FFs) to validate the GOOSE method and examine the errors in the DIXON method. Then, we compared the 2 methods in the tongue, soft palate, pharyngeal wall, and parapharyngeal fat pad of 63 healthy participants to further assess the errors caused by the DIXON method. Six participants were excluded from the comparison of the tongue FFs because of technical failures. Paired Student t tests were performed on FFs to detect significant differences between the 2 methods. All measures were obtained using 3 T Siemens MRI scanners. RESULTS: In the phantoms, the FFs measured by GOOSE agreed with the true FF, with only a 1.2% mean absolute error. However, the same measure by DIXON had a 10.5% mean absolute error. The FFs obtained by DIXON were significantly lower than those obtained by GOOSE (P < 0.0001) in the human participants. We found strong correlations between GOOSE and DIXON in the tongue (R2 = 0.90), soft palate (R2 = 0.66), and parapharyngeal fat pad (R2 = 0.88), but the correlation was weaker in the posterior pharyngeal walls (R2 = 0.32) in participants. CONCLUSIONS: The widely used 2-point DIXON underestimated FFs, relative to GOOSE, in phantom measurements and tissues studied in vivo. Thus, an advanced method, such as GOOSE, that uses multiecho complex data is preferred for estimating FF.


Assuntos
Palato Mole , Apneia Obstrutiva do Sono , Humanos , Palato Mole/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Língua/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
7.
Sci Rep ; 12(1): 6037, 2022 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-35411058

RESUMO

Plasma electrolytic oxidation (PEO) is a surface-treatment process extensively used to protect the surfaces of light metals such as Mg, Al, and Ti. Here, we report an environmentally friendly PEO process that uses nitrogen-containing electrolytes and low voltages (120 V) to form ~ 12 micron thick, uniform, adherent and porous oxide coatings on T1 titanium alloy surfaces. We evaluated the influence of nitrogenation by comparing the coatings to alloys treated in PEO baths without nitrogen-containing compounds. Both sets of samples exhibited basalt-like morphologies with distinct variation in the pore structures. The composition analyses showed that the coatings were primarily composites of titanium oxides and silicates. The T1 Ti alloys treated with nitrogen-containing electrolytes also contained TiC and TiN. This is the first ever report of producing TixOy, Ti-Si-O, TiC, and TiN composite coatings using a single PEO bath without carbide/nitride nanoparticles. The bandgaps of the coatings suggested visible light functionality. The use of nitrogen-based compounds in the PEO baths improved the hardness of the oxide layers but introduced stress-induced cracking which are potentially responsible for the reduction in corrosion resistance of the nitride and carbide containing coatings.

8.
ACS Omega ; 7(10): 8570-8580, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35309481

RESUMO

Low-density metals such as Mg and Al (and their alloys) are of high interest for lightweight engineering applications in various industries. Moisture sensitivity, poor tribology, and corrosion susceptibility limit the direct application of these light metals. Plasma electrolytic oxidation (PEO) is extensively used to passivate light metals against corrosion and enhance their mechanical properties. PEO processes in current use are often energy-intensive and use toxic electrolytes. Incorporating composite characteristics to PEO-treated surfaces typically requires modification of electrolytes with nanoparticle addition. Some applications also need post-treatment of oxidized coatings to ensure functionality. We report a versatile, environmentally friendly PEO process that uses organo-silicate electrolytes enriched with nitrogen-containing solutions. The single-step process produces ∼6 µm thick, uniform, adherent, and porous oxide coatings on AZ80 and Al6061 surfaces in 15 min. We evaluated the influence and effectiveness of in situ nitridation by comparing the coating properties with those on alloys treated in PEO electrolytes without nitrogen-containing chemicals. The two sets of coatings were porous with multilayered basalt-like topographies and were composed of metal oxides and metal silicates. Alloys treated in nitrogen-containing electrolytes exhibited the presence of oxynitrides. The use of nitrogen-containing PEO electrolytes resulted in coatings with enhanced mechanical behavior. We found that the corrosion resistance of coatings prepared using low voltages in this study was comparable to the traditional PEO-treated coatings reported in the literature. Nitridation of the coatings, however, appears to have a slightly negative influence on the coatings' corrosion resistance. Our future work will focus on improving the corrosion resistance of the mechanically resilient, nitride-containing PEO-treated coatings.

9.
J Magn Reson Imaging ; 55(5): 1407-1416, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34545639

RESUMO

BACKGROUND: Hepatic iron content (HIC) is an important parameter for the management of iron overload. Non-invasive HIC assessment is often performed using biopsy-calibrated two-dimensional breath-hold Cartesian gradient echo (2D BH GRE) R2* -MRI. However, breath-holding is not possible in most pediatric patients or those with respiratory problems, and three-dimensional free-breathing radial GRE (3D FB rGRE) has emerged as a viable alternative. PURPOSE: To evaluate the performance of a 3D FB rGRE and validate its R2* and fat fraction (FF) quantification with 3D breath-hold Cartesian GRE (3D BH cGRE) and biopsy-calibrated 2D BH GRE across a wide range of HICs. STUDY TYPE: Retrospective. SUBJECTS: Twenty-nine patients with hepatic iron overload (22 females, median age: 15 [5-25] years). FIELD STRENGTH/SEQUENCE: Three-dimensional radial and 2D and 3D Cartesian multi-echo GRE at 1.5 T. ASSESSMENT: R2* and FF maps were computed for 3D GREs using a multi-spectral fat model and 2D GRE R2* maps were calculated using a mono-exponential model. Mean R2* and FF values were calculated via whole-liver contouring and T2* -thresholding by three operators. STATISTICAL TESTS: Inter- and intra-observer reproducibility was assessed using Bland-Altman and intraclass correlation coefficient (ICC). Linear regression and Bland-Altman analysis were performed to compare R2* and FF values among the three acquisitions. One-way repeated-measures ANOVA and Wilcoxon signed-rank tests, respectively, were used to test for significant differences between R2* and FF values obtained with different acquisitions. Statistical significance was assumed at P < 0.05. RESULTS: The mean biases and ICC for inter- and intra-observer reproducibility were close to 0% and >0.99, respectively for both R2* and FF. The 3D FB rGRE R2* and FF values were not significantly different (P > 0.44) and highly correlated (R2 ≥ 0.98) with breath-hold Cartesian GREs, with mean biases ≤ ±2.5% and slopes 0.90-1.12. In non-breath-holding patients, Cartesian GREs showed motion artifacts, whereas 3D FB rGRE exhibited only minimal streaking artifacts. DATA CONCLUSION: Free-breathing 3D radial GRE is a viable alternative in non-breath-hold patients for accurate HIC estimation. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Sobrecarga de Ferro , Ferro , Adolescente , Biópsia , Criança , Feminino , Humanos , Sobrecarga de Ferro/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Biotechnol Lett ; 26(3): 197-201, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15049362

RESUMO

Although a non-sterile, undiluted carpet dye effluent (containing two anthraquinone dyes) did not support growth of Trametes versicolor, the pre-grown fungus removed 95% of its color in shake-flasks after 10 h of incubation. After decoloration, the COD of the cell-free supernatant increased and the toxicity was unchanged as determined by the Microtox assay using Vibrio fischeri. Decoloration rates decreased when either glucose alone or Mn2+ and glucose were added. T. versicolor, immobilized on jute twine in a rotating biological contacting reactor, also decolorized four successive batches of the effluent. There was no decoloration in any of the uninoculated, non-sterile controls.


Assuntos
Basidiomycota/crescimento & desenvolvimento , Basidiomycota/metabolismo , Reatores Biológicos/microbiologia , Cor , Corantes/metabolismo , Resíduos Industriais/prevenção & controle , Indústria Têxtil/métodos , Purificação da Água/métodos , Basidiomycota/efeitos dos fármacos , Biodegradação Ambiental , Glucose/metabolismo , Magnésio/farmacologia , Consumo de Oxigênio/efeitos dos fármacos , Consumo de Oxigênio/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...